PRODUCT OVERVIEW & SYSTEM POSITIONING

The 480kW Isolated Air-Cooled DC Charging Station represents a paradigm shift in high-power electric vehicle (EV) fleet and commercial depot charging infrastructure. Designed for demanding duty cycles, this platform integrates galvanically isolated DC fast charging with advanced thermal management, targeting heavy-duty vehicles, public transportation hubs, and logistics centers. Unlike conventional grid-tied chargers, this unit features an integrated isolated power stage that decouples the vehicle battery from grid transients, harmonics, and ground faults, ensuring maximum safety and battery longevity.

480kW Isolated Air-Cooled DC Charging Station - Official Commercial BESS Technical Overview & Datasheet details

SYSTEM ARCHITECTURE & SAFETY ISOLATION

At the core of the station lies a modular, high-frequency isolated DC-DC converter topology utilizing silicon carbide (SiC) MOSFETs. This design provides complete electrical separation between the AC grid input and the DC output to the EV, eliminating common-mode leakage currents and enabling unrestricted operation on ungrounded or high-resistance grounded DC microgrids. The front-end active rectifier ensures a unity power factor (PF > 0.99) and low total harmonic distortion (THDi < 3%), while the isolated DC stage delivers stable, low-ripple charging current. KEY FEATURES - True Galvanic Isolation: 1500Vdc input-output isolation per IEC 61851-23, ensuring zero DC injection into the grid and protecting EV batteries from ground faults. - High-Density Air-Cooled Thermal Architecture: Forced-air cooling with IP54-rated fan arrays and redundant airflow path; operates from -30°C to +55°C without liquid coolant maintenance. - Dynamic Power Sharing: 480kW total power configurable across 2 to 6 independent DC output ports (CCS1, CCS2, or CHAdeMO), with automatic load balancing per ISO 15118. - Wide Output Voltage Range: 150Vdc to 1000Vdc, compatible with 400V and 800V class EV batteries, including future 1000V architectures. - Grid-Support Functions: Reactive power compensation, voltage ride-through, and export limitation as standard. - Cybersecurity Ready: Secure boot, encrypted communication (TLS 1.3), and role-based access control. TECHNICAL SPECIFICATIONS AC INPUT (Grid Side) - Nominal Voltage: 480V AC ±10%, 3-phase + PE - Frequency: 50/60 Hz ±5 Hz - Max Input Current: 600A - Power Factor: >0.99 (full load)
– THDi: <3% (full load) DC OUTPUT (EV Side) - Total Rated Power: 480 kW continuous - Output Voltage Range: 150 – 1000 Vdc - Max Output Current (single port): 500A (liquid-cooled cable) / 300A (air-cooled cable) - Voltage Accuracy: ±0.5% of full scale - Current Accuracy: ±1% of setpoint - Isolation Type: Galvanic, high-frequency transformer - Efficiency (Full Load): >94.5% (incl. auxiliary loads)

Parameter Specification
Rated Output Power 480 kW continuous
Max Output Voltage 1000 Vdc
Max Output Current (total) 960A (dual ports fully loaded)
Number of DC Ports 2 to 6 (configurable)
Cooling Method Forced air, redundant fans
Operating Temperature -30°C to +55°C (derated above +45°C)
AC Input Voltage 480V AC ±10%, 3-phase
Peak Efficiency >94.5%
Isolation Voltage Rating 1500Vdc primary-secondary
Standards IEC 61851-23, -24, ISO 15118, OCPP 2.0.1

PROTECTIONS & COMPLIANCE

– Protections: Input over/under voltage, output overcurrent, short circuit (hardware and software), DC ground fault, overtemperature (winding and heatsink), reverse polarity, surge protection (Type 1+2 on AC, Type 2 on DC).
– Standards Compliance: IEC 61851-23 (DC charging), IEC 61851-24 (communication), ISO 15118 (plug & charge, V2G ready), UL 2202 (pending), IEC 61000-6-2/4 (EMC immunity/emission).
– Environmental: IP54 (indoor/outdoor installation), IK10 (impact resistant enclosure), altitude up to 2000m (derated above).
– Noise Emission: <65 dB(A) @ 1m (fan at full speed). OPERATIONAL & USER INTERFACE - Local HMI: 10.1" industrial touchscreen with fault diagnostics, energy metering per session, and RFID/NFC reader. - Remote Management: 4G/LTE, Ethernet (Modbus TCP, OCPP 1.6J/2.0.1), optional Wi-Fi. - Backend Compatibility: OCPP-compliant any central system (charge point management system). - Metering: MID-compliant DC energy meter (accuracy class B). - Firmware Update: Over-the-air (OTA) with rollback protection. MECHANICAL - Dimensions (W x H x D): 1600 x 2200 x 900 mm - Weight: 1250 kg (excluding cables and accessories) - Enclosure Material: Galvanized steel with anti-corrosion coating (C5-M optional) - Cooling: Forced air, rear intake / front exhaust, removable washable air filters. - Cable Management: Integrated hangers and strain relief for up to 6 DC cables (5m each, optional 10m). 480kW Isolated Air-Cooled DC Charging Station - Official Commercial BESS Technical Overview & Datasheet details

INSTALLATION & DEPLOYMENT NOTES

– Minimum clearances: 800mm front (access), 300mm rear (air exhaust), 500mm each side.
– Electrical connection: Bottom entry AC cable (3x 240mm² + PE) and DC cables via gland plates.
– Foundation: Level concrete pad (min 1600 x 2200 mm) with anchor bolts.
– Ambient Conditions: -30°C to +55°C operational (derating >45°C), 5% to 95% RH non-condensing.
– Compliance: CE, UKCA, CB Scheme certificate ready. RCM, EAC available on request.